{"id":57,"date":"2017-04-13T15:18:03","date_gmt":"2017-04-13T15:18:03","guid":{"rendered":"http:\/\/nexionscorp.com\/?page_id=57"},"modified":"2017-04-17T20:23:08","modified_gmt":"2017-04-17T20:23:08","slug":"high-pressure-ac-systems","status":"publish","type":"page","link":"https:\/\/nexionscorp.com\/?page_id=57","title":{"rendered":"High Pressure A\/C Systems"},"content":{"rendered":"<div id=\"pl-57\"  class=\"panel-layout\" ><div id=\"pg-57-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-57-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-57-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<div id=\"pagecols\">\n<div id=\"column1\">\n<div id=\"colbody1\" class=\"colbody\">\n<div id=\"pgbldblk5\" class=\"building_block\">\n<div id=\"body_pgbldblk5\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"\" valign=\"top\" width=\"100%\">\n<h2 align=\"center\"><span style=\"font-size: x-large;\"><span style=\"color: #ff0000;\">High Pressure Marine Air Conditioning Systems<\/span><\/span><\/h2>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk27\" class=\"building_block\">\n<div id=\"body_pgbldblk27\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"\" valign=\"top\" width=\"100%\">\n<h2 align=\"center\"><span style=\"color: #0000ff;\">Specifications<\/span><\/h2>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk33\" class=\"building_block\">\n<div id=\"body_pgbldblk33\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"top\" width=\"50%\">\n<table border=\"0\" summary=\"image table\" width=\"370\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\" valign=\"top\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.nexionscorp.com\/images\/345_72kHP-6.jpg\" alt=\"\" width=\"345\" height=\"316\" border=\"0\"\/><\/td>\n<\/tr>\n<tr>\n<td align=\"center\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"\" valign=\"top\" width=\"50%\"><center><span style=\"color: #0000ff; font-size: x-large;\"><br \/><\/span><\/p>\n<div align=\"left\"><span style=\"color: #0000ff; font-size: x-large;\">Commercial quality water cooled units from 2-10 Ton with digital controls<\/p>\n<p><\/span><\/div>\n<p><\/center><\/p>\n<div align=\"left\">&nbsp;<\/div>\n<p><center><\/p>\n<div align=\"left\"><span style=\"color: #0000ff; font-size: x-large;\">7 Ton unit shown with 12-2\" supply ducts<\/span><\/div>\n<p><\/center><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk40\" class=\"building_block\">\n<div id=\"body_pgbldblk40\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"\" valign=\"top\" width=\"100%\">\n<h4><span style=\"font-size: large;\">Primarily used on workboats, larger vessels, ships and aircraft, high-pressure systems eliminate the need to run water and condensate lines throughout the vessel which greatly reduces the installation expense, although you do lose independant temperature control in the individual spaces.<\/span><\/h4>\n<h4><span style=\"font-size: large;\">The conditioned air is compressed and transported throughout the vessel in relatively small diameter tubing to the different locations which may be quite distant from the air conditioning unit. Because the compressed air is warmer than uncompressed air, insulated ducting\/tubing is usually not necessary - the air drops to design temperature only when it finally reaches atmospheric pressure in the individual cabins.<\/span><\/h4>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk45\" class=\"building_block\">\n<div id=\"body_pgbldblk45\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"\" valign=\"top\" width=\"100%\">\n<h4 align=\"center\"><span style=\"font-size: medium;\">Shown below is a 20 Ton, vertical discharge unit:<\/span><\/h4>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk50\" class=\"building_block\">\n<div id=\"body_pgbldblk50\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"top\" width=\"100%\">\n<table border=\"0\" summary=\"image table\" width=\"487\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\" valign=\"top\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.nexionscorp.com\/images\/462_FMAC20HPS-5.gif\" alt=\"\" width=\"462\" height=\"211\" border=\"0\"\/><\/td>\n<\/tr>\n<tr>\n<td align=\"center\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk55\" class=\"building_block\">\n<div id=\"body_pgbldblk55\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"\" valign=\"top\" width=\"100%\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk60\" class=\"building_block\">\n<div id=\"body_pgbldblk60\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"top\" width=\"100%\">\n<table border=\"0\" summary=\"image table\" width=\"486\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\" valign=\"top\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.nexionscorp.com\/images\/461_FMAC20HPS-6.gif\" alt=\"\" width=\"461\" height=\"237\" border=\"0\"\/><\/td>\n<\/tr>\n<tr>\n<td align=\"center\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk65\" class=\"building_block\">\n<div id=\"body_pgbldblk65\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"\" valign=\"top\" width=\"100%\">&nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk70\" class=\"building_block\">\n<div id=\"body_pgbldblk70\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"top\" width=\"100%\">\n<table border=\"0\" summary=\"image table\" width=\"410\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\" valign=\"top\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.nexionscorp.com\/images\/385_ductplan.gif\" alt=\"\" width=\"385\" height=\"341\" border=\"0\"\/><\/td>\n<\/tr>\n<tr>\n<td align=\"center\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"pgbldblk75\" class=\"building_block\">\n<div id=\"body_pgbldblk75\" class=\"blockbody\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr align=\"\" valign=\"\">\n<td colspan=\"1\" rowspan=\"1\" align=\"\" valign=\"top\" width=\"100%\"><center><span style=\"color: #ff0000;\">Approximate Specifications<\/span><\/p>\n<table border=\"6\" width=\"643\" cellspacing=\"2\" cellpadding=\"2\" align=\"center\">\n<caption align=\"BOTTOM\">\n<blockquote><p><span style=\"color: #000000;\">Higher voltages and 50Hz available for an additional fee. Return air ducting usually necessary depending on unit location. Discharge ducting can be from 1\" - 4\" multiple ducts or a single 6-10\" duct. Add about 12\" to the overall height for a vertical discharge or length for a side discharge unit - about the same in width and length for return ducting if needed.<\/span><\/p><\/blockquote>\n<\/caption>\n<tbody>\n<tr>\n<td width=\"19%\" height=\"52\"><center>&nbsp;Model<\/center><\/td>\n<td width=\"11%\"><center><b><span style=\"color: #0000ff;\">BTUs of cooling<\/span><\/b><\/center><\/td>\n<td width=\"8%\"><center>&nbsp;<b><span style=\"color: #0000ff;\">KW<\/span><\/b><span style=\"color: #0000ff;\"> of electric heat<\/span><\/center><\/td>\n<td width=\"11%\"><center>&nbsp;<b><span style=\"color: #0000ff;\">Length <\/span><\/b><span style=\"color: #0000ff;\">in inches<\/span><\/center><\/td>\n<td width=\"9%\"><center><b><span style=\"color: #0000ff;\">Width <\/span><\/b><span style=\"color: #0000ff;\">in inches<\/span><\/center><\/td>\n<td width=\"10%\"><center>&nbsp;<b><span style=\"color: #0000ff;\">Height <\/span><\/b><span style=\"color: #0000ff;\">in inches<\/span><\/center><\/td>\n<td width=\"12%\"><center>&nbsp;<b><span style=\"color: #0000ff;\">Amps (cool)<\/span><\/b><\/center><\/td>\n<td width=\"9%\"><center>&nbsp;<b><span style=\"color: #0000ff;\">Amps (heat)<\/span><\/b><\/center><\/td>\n<td width=\"11%\"><center>&nbsp;<b><span style=\"color: #0000ff;\">Weight <\/span><\/b><span style=\"color: #0000ff;\">pounds<\/span><\/center><\/td>\n<\/tr>\n<tr>\n<td width=\"19%\" height=\"18\"><center>&nbsp;FMAC2HPS<\/center><\/td>\n<td width=\"11%\"><center>24,000<\/center><\/td>\n<td width=\"8%\"><center>4<\/center><\/td>\n<td width=\"11%\"><center>26<\/center><\/td>\n<td width=\"9%\"><center>20<\/center><\/td>\n<td width=\"10%\"><center>24<\/center><\/td>\n<td width=\"12%\"><center>15@230\/1<\/center><\/td>\n<td width=\"9%\"><center>4KW<\/center><\/td>\n<td width=\"11%\"><center>225<\/center><\/td>\n<\/tr>\n<tr>\n<td width=\"19%\" height=\"18\"><center>&nbsp;FMAC3HPS<\/center><\/td>\n<td width=\"11%\"><center>36,000<\/center><\/td>\n<td width=\"8%\"><center>4<\/center><\/td>\n<td width=\"11%\"><center>26<\/center><\/td>\n<td width=\"9%\"><center>24<\/center><\/td>\n<td width=\"10%\"><center>26<\/center><\/td>\n<td width=\"12%\"><center>24@230\/1<\/center><\/td>\n<td width=\"9%\"><center>4KW<\/center><\/td>\n<td width=\"11%\"><center>250<\/center><\/td>\n<\/tr>\n<tr>\n<td width=\"19%\" height=\"18\"><center>&nbsp;FMAC4HPS<\/center><\/td>\n<td width=\"11%\"><center>48,000<\/center><\/td>\n<td width=\"8%\"><center>6<\/center><\/td>\n<td width=\"11%\"><center>26<\/center><\/td>\n<td width=\"9%\"><center>24<\/center><\/td>\n<td width=\"10%\"><center>28<\/center><\/td>\n<td width=\"12%\"><center>29@230\/1<\/center><\/td>\n<td width=\"9%\"><center>6-8KW<\/center><\/td>\n<td width=\"11%\"><center>275<\/center><\/td>\n<\/tr>\n<tr>\n<td width=\"19%\" height=\"18\"><center>&nbsp;FMAC5HPS<\/center><\/td>\n<td width=\"11%\"><center>60,000<\/center><\/td>\n<td width=\"8%\"><center>8<\/center><\/td>\n<td width=\"11%\"><center>26<\/center><\/td>\n<td width=\"9%\"><center>24<\/center><\/td>\n<td width=\"10%\"><center>28<\/center><\/td>\n<td width=\"12%\"><center>35@230\/1<\/center><\/td>\n<td width=\"9%\"><center>6-8KW<\/center><\/td>\n<td width=\"11%\"><center>325<\/center><\/td>\n<\/tr>\n<tr>\n<td width=\"19%\" height=\"18\"><center>&nbsp;FMAC7HPS<\/center><\/td>\n<td width=\"11%\"><center>84,000<\/center><\/td>\n<td width=\"8%\"><center>10<\/center><\/td>\n<td width=\"11%\"><center>26<\/center><\/td>\n<td width=\"9%\"><center>24<\/center><\/td>\n<td width=\"10%\"><center>32<\/center><\/td>\n<td width=\"12%\"><center>21@230\/3<\/center><\/td>\n<td width=\"9%\"><center>5-10KW<\/center><\/td>\n<td width=\"11%\"><center>390<\/center><\/td>\n<\/tr>\n<tr>\n<td width=\"19%\" height=\"19\"><center>&nbsp;FMAC10HPS<\/center><\/td>\n<td width=\"11%\"><center>120,000<\/center><\/td>\n<td width=\"8%\"><center>16<\/center><\/td>\n<td width=\"11%\"><center>44<\/center><\/td>\n<td width=\"9%\"><center>34<\/center><\/td>\n<td width=\"10%\"><center>32<\/center><\/td>\n<td width=\"12%\"><center>37@230\/3<\/center><\/td>\n<td width=\"9%\"><center>10-15KW<\/center><\/td>\n<td width=\"11%\"><center>460<\/center><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/center><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"column2\">&nbsp;<\/div>\n<div id=\"column3\">&nbsp;<\/div>\n<\/div>\n<div id=\"measurescroll\">&nbsp;<\/div>\n<table id=\"other_footer\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"middle\">\n<div align=\"center\"><b><span style=\"font-family: arial, verdana, sans-serif; font-size: medium;\">For all sales and general inquiries please call Nexions Corp.<br \/>p. 305-234-6042 or e-mail us at <\/span><\/b><a href=\"mailto:info@nexionscorp.com\"><b><span style=\"font-family: arial, verdana, sans-serif; font-size: medium;\">info@nexionscorp.com<\/span><\/b><\/a><\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>High Pressure Marine Air Conditioning SystemsSpecifications&nbsp;Commercial quality water cooled units from 2-10 Ton with digital controls&nbsp;7 Ton unit shown with 12-2&#8243; supply ductsPrimarily used on workboats, larger vessels, ships and aircraft, high-pressure systems eliminate the need to run water and &hellip; <a href=\"https:\/\/nexionscorp.com\/?page_id=57\">Continued<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-portfolio.php","meta":{"footnotes":""},"class_list":["post-57","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/nexionscorp.com\/index.php?rest_route=\/wp\/v2\/pages\/57","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nexionscorp.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/nexionscorp.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/nexionscorp.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nexionscorp.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=57"}],"version-history":[{"count":3,"href":"https:\/\/nexionscorp.com\/index.php?rest_route=\/wp\/v2\/pages\/57\/revisions"}],"predecessor-version":[{"id":342,"href":"https:\/\/nexionscorp.com\/index.php?rest_route=\/wp\/v2\/pages\/57\/revisions\/342"}],"wp:attachment":[{"href":"https:\/\/nexionscorp.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=57"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}